1. Install:

| CAUTION: After tightening the screws, make sure the oil pump turns smoothly. |
Assembling the oil pump
Shift shaftPeriodic maintenance and lubrication chart
NOTE:
The annual checks must be performed every year, except if a
kilometer-based maintenance,
or for the UK, a mileage-based maintenance, is performed instead.
From 30000 km (17500 mi), repeat the maintenance intervals starting
from 6000 km (3500 mi).
Items marked with an asterisk s ...
Checking the ignition coil
1. Check:
Primary coil resistance
Out of specification Replace.
a. Disconnect the ignition coil connectors from
the ignition coil terminals.
b. Connect the pocket tester ( × 1)
to the ignition
coil as shown.
Positive tester probe
red/white "1"
Negative tester probe
orange ...
Checking the relays
Check each switch for continuity with the pocket
tester. If the continuity reading is incorrect, replace
the relay.
1. Disconnect the relay from the wire harness.
2. Connect the pocket tester ( × 1) and battery
(12 V) to the relay terminal as shown.
Check the relay operation.
Out ...