Yamaha YZF-R125 Service Manual: Diagnostic mode

It is possible to monitor the sensor output data or check the activation of actuators with the FI diagnostic tool connected to the vehicle and set to the normal mode or the diagnostic monitoring mode.


Troubleshooting method
The engine operation is not normal and the engine trouble warning light comes on. 1. Check: Fault code number a. Check the fault code number displayed on the FI diagnostic tool. b. Identi ...

Setting the normal mode
NOTE: The engine speed, coolant temperature, and fault code, if detected, can be displayed on the LCD of the FI diagnostic tool when the tool is connected to the vehicle and is set to the normal ...

Other materials:

Storage
Short-term Always store your motorcycle in a cool, dry place and, if necessary, protect it against dust with a porous cover. NOTICE Storing the motorcycle in a poorly ventilated room or covering it with a tarp, while it is still wet, will allow water and humidity to seep in and ...

Checking the valve seats
The following procedure applies to all of the valves and valve seats. 1. Eliminate: Carbon deposits (from the valve face and valve seat) 2. Check: Valve seat Pitting/wear Replace the cylinder head. 3. Measure: Valve seat width C "a" Out of specification Replace the ...

Adjusting the valve clearance
The following procedure applies to all of the valves. NOTE: Valve clearance adjustment should be made on a cold engine, at room temperature. When the valve clearance is to be measured or adjusted, the piston must be at top dead center (TDC) on the compression stroke. 1. Remove: ...