Yamaha YZF-R125 Service Manual: Diagnostic mode

It is possible to monitor the sensor output data or check the activation of actuators with the FI diagnostic tool connected to the vehicle and set to the normal mode or the diagnostic monitoring mode.


Troubleshooting method
The engine operation is not normal and the engine trouble warning light comes on. 1. Check: Fault code number a. Check the fault code number displayed on the FI diagnostic tool. b. Identi ...

Setting the normal mode
NOTE: The engine speed, coolant temperature, and fault code, if detected, can be displayed on the LCD of the FI diagnostic tool when the tool is connected to the vehicle and is set to the normal ...

Other materials:

Installing the crankshaft
1. Install: Crankshaft "1" NOTE: Install the crankshaft with the crankshaft installer pot "2", crankshaft installer bolt "3", adapter (M12) "4" and spacer (crankshaft installer) "5". CAUTION:To avoid scratching the crankshaft and to ease the installation procedure, lubricate ...

Replacing the fuses
Replacing the fuses Fuse box Spare fuse Headlight fuse Signaling system fuse Ignition fuse Radiator fan fuse Main fuse The fuse box is located under the rider seat. If a fuse is blown, replace it as follows. Turn the key to "OFF" and turn off the electrical circuit i ...

Adjusting the throttle cable free play
NOTE: Prior to adjusting the throttle cable free play, the engine idling speed should be adjusted. 1. Check: Throttle cable free play "a" Out of specification →Adjust. 2. Remove: Right side panel Refer to "GENERAL CHASSIS" on page 4-1. 3. Adjust: Throttle cable f ...