Right viewChecking the relays
Check each switch for continuity with the pocket
tester. If the continuity reading is incorrect, replace
the relay.
1. Disconnect the relay from the wire harness.
2. Connect the pocket tester ( × 1) and battery
(12 V) to the relay terminal as shown.
Check the relay operation.
Out ...
Checking the turn signal relay
1. Check:
Turn signal relay input voltage
Out of specification →The wiring circuit
from
the main switch to the turn signal relay coupler
is faulty and must be repaired.
a. Connect the pocket tester (DC 20 V) to the
turn signal relay terminal as shown.
- Positive tester probe
b ...
Checking the diode
1. Check:
Diode
Out of specification Replace.
NOTE:
The pocket tester or the analog pocket tester
readings are shown in the following table.
a. Disconnect the diode from the wire harness.
b. Connect the pocket tester ( × 1)
to the diode
terminals as shown.
c. Check the diod ...