Installing the water pump
Fuel tankChecking the thermostat
1. Check:
Thermostat
Does not open at 80.5-83.5 C (176.9-182.3
F) Replace.
a. Suspend the thermostat "1" in a container "2"
filled with water.
b. Slowly heat the water "3".
c. Place a thermometer "4" in the water.
d. While stirring the water, observe the thermostat
and th ...
Checking the lean angle sensor
1. Remove:
Lean angle sensor
2. Check:
Lean angle sensor output voltage
Out of specification Replace.
a. Connect the lean angle sensor to the wire
harness.
b. Connect the pocket tester (DC 20 V) to the
lean angle sensor coupler as shown.
Positive tester probe
yellow/green "1"
Neg ...
Checking the fuses
The following procedure applies to all of the fuses.
CAUTION:To avoid a short circuit, always turn the
main
switch to "OFF" when checking or replacing
a fuse.
1. Remove:
Rider seat
Refer to "GENERAL CHASSIS" on page 4-1.
2. Check:
Fuse
a. Connect the pocket te ...